Projects — where we've installed ventilation

A selection from more than 250 projects all over Slovakia. For each venue we describe the brief, what we found on site and how we solved it — including cases where we were fixing someone else's work. And for each one, how many days the venue had to stay closed: in Bátka it was a single day.

Choose the type of venue closest to yours.

Restaurants and roadside restaurants

Venue 03/roadside restaurant

Zlatý strom roadside restaurant

Bartošova Lehôtka · Banskobystrický kraj · July 2026

This roadside restaurant's kitchen had inline fans installed that didn't work. The kitchen was very hot — the cooks were working in conditions nobody can stand for long. I designed and drew a hood with a kitchen fan and two supply systems: one to the kitchen, the other to the dining room. During installation further faults in the original set-up came to light, so in the end we rebuilt the whole ventilation completely.

What we did
Design and installation of a hood with a kitchen fan, two supply systems — to the kitchen and to the dining room, a complete rebuild of the original ventilation

Where it is. The restaurant stands on the I/65 road between Žiar nad Hronom and Kremnica. A transit venue means rush-hour surges and a kitchen that cooks practically without a break — the ventilation here carries a completely different load from a restaurant in town.

What I found. Inline fans that weren't doing their job, and a kitchen that was unbearably hot. The heat from the ranges and fryers had nowhere to go and built up in the room.

What I designed. A hood with a kitchen fan above the cooking line and two separate supply systems. One serves the kitchen, the other the dining room. Supply air is the part most often left out — without it the extraction never reaches its capacity, however strong the motor.

How it turned out. During installation further faults in the original set-up appeared, so we rebuilt the ventilation completely rather than piecemeal. The people who judge the result best are those who stand in the kitchen every day — and they're happy.

02

Designed

— The solution, sketched on site
03

Built

— The finished job

Venue 01/family restaurant

Lucky family restaurant

Lučenec · Banskobystrický kraj · June 2026

A family restaurant that has been cooking lunches in Lučenec for thirty years built an extension to its kitchen and dining room. They called me about a canopy above the range and combi oven. During the survey I explained to the owners what's most often left out in renovations: without controlled air supply the extraction wouldn't reach even half its capacity. So I installed an extraction fan with silencers and a ducted fresh-air supply system with electric heating that serves both the kitchen and the dining room.

What we did
Canopy above the range and combi oven, extraction fan with silencers, ducted fresh-air supply with electric heating to the kitchen and dining room, capacity control

The brief. The Lucky restaurant in Lučenec has been preparing lunches for thirty years. Expanding the venue added a new kitchen and dining room, and with them the question of how to remove heat and steam from the range and combi oven.

What I designed. Besides the canopy I dealt with the other half of the system — the air supply. Extraction removes a certain amount of air, and the same amount has to get back into the venue. Without that, negative pressure builds up, the draw drops and air is sucked in through gaps.

The installation. I placed the extraction fan on the roof and added silencers so the motor can't be heard in the kitchen. Fresh air comes in through a ducted system with electric heating — so no cold stream blows into the venue in winter. The distribution serves both the kitchen and the dining room. The system's output can be adjusted to how much is being cooked.

01

Saw

— What I found on site
02

Designed

— The solution, sketched on site
03

Built

— The finished job

Venue 06/family restaurant

Pearl restaurant

Trenčín · Trenčiansky kraj · May 2025

A family restaurant in Trenčín with ventilation more than thirty years old. Interestingly, they had already bought the extractors themselves — but each canopy had its own built-in fan. I told them straight that it wouldn't work that way, and helped them remove those fans from inside so at least the hoods themselves could be used. In the end we installed one kitchen fan and connected both canopies to it. I'll come back to sort out the air supply to the dining room closer to winter.

What we did
Removal of the built-in fans from the purchased hoods, installation of a single kitchen fan, connection of the hoods, extraction ductwork
Coming next
Air supply system for the dining room — before winter

The situation. A family restaurant that has been running for decades. The ventilation dated from the original building and was more than thirty years old.

What happened before I arrived. The owners had already bought extractors. Each had its own fan right in the canopy. It sounds logical — two canopies, two fans. In practice it doesn't work: two separate motors pulling into a shared duct get in each other's way, and the resulting draw is lower than with one correctly sized fan.

What I did. I didn't start by saying everything had to be bought again. I removed the fans from the canopies from inside so the canopies they'd already paid for could be used. Then we installed one kitchen fan outside the kitchen and connected both hoods to it.

What's still to come. Fresh-air supply to the dining room. We agreed to do it before winter — that's when the difference between ventilation with and without supply is felt most.

01

Saw

— What I found on site
03

Built

— The finished job

Venue 04/restaurant

Ti amo — Italian restaurant

Trnava · Trnavský kraj · June 2026

Before I arrived, this Trnava restaurant had two rectangular inline fans that were never meant for removing kitchen air. One no longer worked, the other was practically broken. Their grilles were so clogged with grease that air could barely get through. I removed them and in their place installed one kitchen fan designed for food service and an air supply system for the kitchen.

What we did
Removal of two unsuitable rectangular inline fans, installation of a kitchen fan, air supply system for the kitchen

What I found. Two rectangular inline fans on the roof. That type of fan is meant for ordinary ventilation, not for removing greasy air from a professional kitchen. The difference isn't motor power, but that a kitchen fan tolerates grease and can be cleaned. An ordinary inline fan simply clogs up.

Which is exactly what had happened. The grilles were covered with a thick layer of grease and dirt. One fan no longer worked at all, the other was practically broken.

The solution. I removed both and replaced them with one kitchen fan designed for this kind of venue. At the same time I added an air supply system for the kitchen — without it even the new fan wouldn't reach its capacity.

01

Saw

— What I found on site
03

Built

— The finished job

Venue 02/restaurant

MACHO restaurant and guesthouse

Malženice · Trnavský kraj · July 2026

At the MACHO restaurant the inline fan and grease filter were completely clogged with grease. They had replaced the fan twice before I arrived and the extraction still didn't work. The cause wasn't the motor — the air had nowhere to go. I removed all the redundant components that were only robbing the system of pressure, and installed a kitchen fan on the building's façade.

What we did
Removal of a faulty inline fan and a clogged grease filter, removal of redundant system components, installation of a kitchen fan on the building's façade

What I found. An inline fan in the duct and in front of it a grease filter completely clogged with grease. The system also had components that had no business being on the route and only added resistance.

Why replacing the fan twice didn't help. This is the most common mistake I come across in venues. When the extraction doesn't draw, people reach for a more powerful motor. But if the air has nowhere to go, a stronger fan just hums louder and uses more. The draw stays the same.

The solution. I removed the unnecessary components from the system and moved the fan from the duct to the building's façade. A motor outside the room means no noise in the kitchen, and it's accessible for maintenance.

03

Built

— The finished job

Venue 09/restaurant

Village restaurant

Bátka · Banskobystrický kraj · April 2026

I was called here for a survey in November 2025. I prepared a quote, but the client weighed it up and took a long time to answer. In March 2026 he got in touch himself: the fan was humming, the air wasn't being extracted and the hoods were working ineffectively. We installed three supply systems totalling 6,000 m³/h and two extraction systems with kitchen fans totalling 7,000 m³/h. The whole installation took a week, and the restaurant had to close for a single day.

What we did
Three supply systems with a total capacity of 6,000 m³/h, two extraction systems with kitchen fans with a total capacity of 7,000 m³/h, rebuilt filters in the existing hoods

Why it didn't work. The client had extraction, but no controlled supply. A fan in that state behaves exactly as he described: it hums and doesn't work. The air sent outside has to come back from somewhere — and if it has no way in, the motor is just fighting negative pressure.

We redid other people's work. Other suppliers had installed the ventilation here before us. It didn't work, so the whole thing was done again — and the client paid twice for the same thing. It's the most expensive mistake in this trade: cheap installation turns out expensive precisely when it has to be done a second time, and the second time is always more complicated than the first, because the space is already finished.

Keeping the venue open during installation. The main challenge wasn't technical. We couldn't close the restaurant for the whole job, because it would have lost a week's takings. We scheduled the work so that most of it was done outside opening hours and in the attic. In the end it was closed for one single day.

Solar panels. During the work it turned out that exhausting air towards the solar panels wasn't allowed. So we moved the extraction route to the opposite side — and on the side with the panels we built the fresh-air intake for the supply systems instead. The constraint became part of the solution.

Filters in someone else's hoods. The existing hoods had labyrinth filters that catch grease poorly. We replaced them with mesh filters — remaking them on the spot: we cut open the old filters and fitted aluminium mesh and a protective grille inside. It's not work we'd charge for, but it protects the new system and the fans from grease.

Splitting the zones. We divided the extraction zones in the kitchen according to when each part of the kitchen is used. There's no point running full power above a zone that's cold at that hour.

And one extra detail. We had the ducts in the dining room done in a copper colour. It wasn't in the brief, but it suited the space — the ductwork now looks like part of the interior, not equipment that needs hiding.

01

Saw

— What I found on site
03

Built

— The finished job

Venue 10/restaurant / csárda

MALOM CSÁRDA

Tomášikovo · Trnavský kraj · April 2026

I surveyed this place in January 2025. The client was building an extra room onto the restaurant for a new kitchen — in March 2026 the shell was finished and we could start. I installed two hoods with a kitchen fan and fresh-air supply to the kitchen. What took the most time was placing the fan in the attic so it could be opened for grease cleaning and maintenance.

What we did
Two hoods with a kitchen fan, fresh-air supply to the kitchen, fan placed in the attic with access for cleaning

What I saw. An extension for the new kitchen, bare walls and a decision about exactly where the ducts would run. That's the stage when a route can be designed best — nothing has to be worked around and nothing will have to be broken through later.

What I came up with. I sketched the design straight onto photos of the space: where the hoods will be, where the extraction and the supply will run. That way the client sees the solution before anything is bought.

Where the work was. The fan is in the attic. Putting it there isn't the problem — the problem is putting it where it can be reached a year later. Grease always settles on the impeller, and a fan that can't be opened will never be cleaned. So the motor is installed with access for inspection and cleaning.

How it turned out. The kitchen has both extraction and controlled air supply. Supply wasn't in the original brief, but without it the hoods wouldn't reach their capacity.

01

Saw

— What I found on site
02

Designed

— The solution, sketched on site
03

Built

— The finished job

Venue 11/restaurant and beer hall

KASKA PUB — Restaurant & Beer Hall

Sabinov · Prešovský kraj · February 2026

In February 2026 the premises were being renovated for a new restaurant. I came to offer kitchen extraction. I also designed an air supply system, but the client decided to install only the extraction for now. I assembled the island hood from four smaller ones — a piece that big couldn't have been brought into the interior.

What we did
Kitchen extraction, an island hood assembled from four smaller ones, wall hoods, kitchen fan on the façade

The brief. Premises under renovation, a future restaurant with a beer hall. Kitchen extraction was what they asked about.

What I recommended on top. Air supply. Without it, extraction never achieves what's on its rating plate — the air that leaves has to come back. The client decided on extraction alone for now, which is his right. But we ran the routes so supply can be added later without breaking anything open.

An island hood from four smaller ones. A large hood belonged above the island cooking zone. A piece like that won't fit into a finished interior — it won't go through a door or a window. So I assembled it from four smaller ones on the spot. It has a practical advantage too: the extraction duct connects to four separate zones of the big hood, not one throat.

Working half a step ahead. I positioned the ducts at the wall and extraction hoods so that any stainless steel cladding of the hoods would cover them exactly. If the client ever decides on stainless cladding, nothing will need moving.

The fan. The motor is on the façade, outside the kitchen — so it can't be heard in the kitchen and is accessible for maintenance from outside.

01

Saw

— What I found on site
03

Built

— The finished job

Venue 16/pizzeria / restaurant

Pizza 33

Levice · Nitriansky kraj · January 2026

At the Pizza 33 pizzeria in Levice I removed the old, inadequate ventilation and installed new. The extraction has a kitchen fan and a silencer, and it comes with a supply system with filters and an air heater for the kitchen.

What we did
Removal of the old ventilation and installation of new — extraction with a kitchen fan and a silencer, supply system with filters and an air heater

What was here. Old ventilation with rusty ducts and improvised joints that wasn't doing its job. The first step was removing it — you don't connect a new system to one that doesn't work.

New extraction. A hood with grease filters, clean spiral ductwork and a kitchen fan with a silencer. The silencer is the part that's often left out — without it, motor noise travels back through the ducts into the kitchen and the dining room.

Supply with a heater. A separate supply system with filters and an air heater. In winter the heater brings in tempered air, so the extraction doesn't pull cold outdoor air into the kitchen.

Why supply. Extraction without supply creates negative pressure and air is drawn in under the doors — so the solution deals with both sides at once.

01

Saw

— What I found on site
03

Built

— The finished job

Venue 17/Asian restaurant / Vietnamese bistro

NEM Asian restaurant

Trnava · Trnavský kraj · November 2025

The Vietnamese restaurant NEM in Trnava. I installed one large 2600 mm extraction hood and an extraction fan on the façade. A small venue with big problems — a fragile ceiling and wall, a restricted roof edge and the building owner's requirements.

What we did
One large 2600 mm extraction hood, extraction fan on the front of the façade, anchoring into load-bearing wooden beams and a penetration through the wall

Fragile ceiling and wall. Both the ceiling and the wall were very fragile. So I located the load-bearing wooden beams in the ceiling and anchored the hood to them. I drilled through the full thickness of the wall and fixed the fan brackets with threaded bolts and nuts on the inside — ordinary wall plugs wouldn't have held in a wall like that.

A 2600 mm hood. One large extraction hood above the cooking line, with the extraction fan mounted on the front, on the façade.

The outlet had to work around obstacles. The outlet couldn't go upwards — the roof edge was in the way. So I moved it to the left. At the same time the building owner didn't want the fan any lower, so the solution had to get around both constraints at once.

Small venue, big problems. In venues like this, the result is decided by what you can't see in the photo — where you can anchor and where the outlet is allowed to go.

03

Built

— The finished job

Venue 22/restaurant

Habanero Steak Pub

Vrútky · Žilinský kraj · July 2025

A ventilation project was carried out at the Mexican-cuisine restaurant "Habanero", which specialises in steaks, in Vrútky near Martin. Two supply systems with heat recovery for the kitchen and two extraction systems. The work took place in two phases. The first phase went ahead without closing the restaurant: two supply systems were installed and two kitchen fans with EC motors were mounted outside.

Extended hoods 1100 mm deep with mesh filters were made to order for better removal of grease from the air.

With the restaurant owner we originally agreed that the kitchen would be closed for 3 days, but in the end the owner shortened this to 2 days, which of course made the work harder for us. Even so, we managed it in 2 days and finished the installation.

Also during the project — when everything had already been ordered — the restaurant owner decided to add a charcoal oven. That was of course not quite right, because the technology had originally been designed without this oven, but I still managed to arrange it so that we extract this air successfully, that is using the systems that had already been purchased.

In this connection I strongly recommend that before carrying out such demanding projects, technical documentation is always prepared, on the basis of which the ventilation is calculated, so that the result matches expectations.

After the work was finished, the serving staff were instructed on how to carry out maintenance properly, and both the cooks and I are satisfied with the result.

01

Saw

— What I found on site
02

Designed

— Hand sketch of the solution
03

Installation of the first supply system

04

Installation of the second supply system

05

Mounting the kitchen fans outside

06

Installation of hoods and supply grilles in the kitchen

Cafés and patisseries

Venue 19/patisserie

Pralinka patisserie

Liptovský Mikuláš · Žilinský kraj · October 2025

At the Pralinka patisserie in Liptovský Mikuláš I installed vapour extraction for the pastry ovens. Since there's no grease in the extracted air, the solution is built around an inline fan — simpler and cheaper than full kitchen extraction, and entirely sufficient for this type of venue.

What we did
Vapour extraction from pastry ovens using an inline fan, galvanised ducts 100 mm in diameter

The brief. A patisserie isn't a kitchen with fryers and a grill. Bakery and pastry ovens give off steam and heat, but no grease. That changes the whole solution — you don't need grease filters or a powerful kitchen fan, so the price doesn't have to be what full commercial extraction costs either.

Why an inline fan. Since there's no grease in the extracted air, an inline fan fitted straight into the duct is enough. It's cheaper, quieter and easier to maintain — there's nothing to clog with grease.

The ducts. I ran the steam extraction in galvanised pipes 100 mm in diameter, brought from the ovens into a shared branch. Galvanised steel tolerates moisture from the steam without corroding and keeps its shape over longer runs.

Who it makes sense for. Exactly this kind of venue — patisseries, bakeries, places where things are baked but not fried. A solution tailored to the problem, not the most expensive set-up possible.

03

Built

— The finished job

Fast food, kebab and bistros

Venue 05/fast food / kebab

Kebab at the Tesco hypermarket

Žilina · Žilinský kraj · May 2026

A small outlet with a gyros grill by the hypermarket in Žilina. The brief was simple: cheap, functional and fast. I installed a canopy above the grill with an extraction outlet to the façade. Not every venue needs a big system — with a kebab outlet what matters is that the smoke and smell from the grill go outside and don't stay where the staff and customers are.

What we did
Extraction canopy above the gyros grill, extraction outlet to the façade

The brief. A small outlet, limited space, a limited budget. The owner needed a solution that would work and wouldn't cost as much as ventilation for a big restaurant kitchen.

What I did. A canopy above the gyros grill and a direct extraction outlet through the building's façade. A short route means a lower pressure loss, so a smaller, cheaper fan achieves the same result.

Why it works. A gyros grill is a constant source of heat and greasy smoke throughout opening hours. In a small space, without extraction it settles everywhere — on the walls, the ceiling, the customers. The solution doesn't have to be big; it has to be in the right place.

03

Built

— The finished job

Venue 08/Vietnamese bistro

Vietnamese street food

Pezinok · Bratislavský kraj · April 2026

A regular client who is building a chain of Vietnamese bistros in Slovakia asked me to fit out his outlet in Pezinok. In the kitchen I installed extraction for two groups of hoods, each 2400 mm wide, and on the roof a kitchen fan with a capacity of 7800 m³/h. The space is about eight metres high, so we ran all the ductwork from special scaffolding. But what took the most time wasn't the installation — it was coordination with the management of the Tesco store, without which we couldn't start either in the hall or on the roof.

What we did
Extraction for two groups of hoods 2400 mm wide, a 7800 m³/h kitchen fan on the roof, ductwork in a hall about 8 m high

The brief. I know the client from previous venues — he's building a chain of Vietnamese bistros in Slovakia and was opening this branch in Pezinok. The kitchen has two cooking zones, each with a hood 2400 mm wide. Both groups had to be connected to one extraction system.

What was different here — the height. The hall is about eight metres high. In most kitchens ducts are run from a ladder; here that wasn't possible: at that height you need a stable platform, otherwise you can neither measure precisely nor anchor safely. We have special scaffolding for this, and it's what got the installation done on time.

Coordination. The outlet is part of a department store, so every intervention in the roof and every penetration through the structure had to be approved by Tesco's management. Clients usually don't picture this part — yet in buildings like this it takes more time than the installation itself.

The installation. The 7800 m³/h fan stands on the roof on anti-vibration mounts, outside the kitchen — so the motor can't be heard in the hall. The roof penetrations are sealed and the ducts insulated. The client is happy with the result.

03

Built

— The finished job

Venue 13/Vietnamese bistro

Vietnam street food

Žiar nad Hronom · Banskobystrický kraj · December 2025

A Vietnamese restaurant in the Tesco department store building in Žiar nad Hronom. There's a kitchen fan on the roof, four extraction hoods in the kitchen and an air supply system as well — to both the kitchen and the guests' dining area.

What we did
Kitchen fan on the roof, four extraction hoods in the kitchen, air supply system for both the kitchen and the dining room

The brief. A venue in a department store means two things at once: the kitchen has to extract at full power, and no smell may reach the dining area. So the solution doesn't end with the hoods — air supply is just as important, on both sides.

Extraction. Four hoods above the cooking zones, brought together to one kitchen fan on the roof of the building. A motor outside the venue means no noise can be heard in the kitchen or the dining area.

Supply. One system brings fresh air to the kitchen and a second to the dining area. Without it, the extraction would create negative pressure and air would be sucked in under the doors — along with whatever is behind them.

Working in a department store. Every intervention in the roof and the structure goes through approval by the building manager. This part of the project isn't visible in any photo, but in buildings like this it decides the schedule just as much as the installation itself.

03

Built

— The finished job

Venue 14/grill / fast food

PIPI GRIL

Ilava · Trenčiansky kraj · September 2026

The family café and grill PIPI GRIL in Ilava. They used to run a stall; now they'd moved into rented premises and wanted proper ventilation at last — they'd had problems with it in the past. They booked a survey one week and the installation took place the very next.

What we did
Supply and extraction system for a grill outlet — two core-drilled openings in the wall, supply with a filter and a non-return valve, extraction with a fan on the façade

The brief. The business was moving from a stall into a built space. Ventilation was the thing that never really worked in the stall, and the owners didn't want the problem to move with them. Grilling chickens means a lot of heat and greasy vapour — in a small kitchen it can't be handled without both supply and extraction.

Through the wall. I core-drilled two openings into the wall, 330 mm in diameter and 650 mm deep. They aren't just holes for ducts — the diameter and depth determine how much air the system can move, which is why they're calculated in advance, not based on whatever happens to fit.

Supply. In the first opening I fitted the supply system — a filter, a non-return valve and an outside grille. The filter keeps outdoor dirt out; the non-return valve stops air and cold from the street coming back into the kitchen through the system when it's off.

Extraction. The extraction runs through the second opening, with the fan placed on the façade, outside the kitchen. A motor outside means no noise in the small venue, and it's accessible for maintenance from outside.

How it turned out. One week passed from the survey to the finished installation. The venue is happy — and for a small family business where the owner stands in the kitchen himself, that's the only measure that counts.

01

Saw

— What I found on site
03

Built

— The finished job

Venue 15/Vietnamese bistro / sushi

Phở 38 — Vietnamese Bistro & Sushi

Detva · Banskobystrický kraj · December 2026

The Phở 38 Vietnamese bistro in Detva. The kitchen fan is on the roof, ducts with a total length of four metres lead to it, and there are two wall hoods in the kitchen. The extraction hood has four separate connections so the draw is spread evenly over its whole area.

What we did
Kitchen fan on the roof, ductwork with a total length of 4 m, two wall hoods and four connections to the extraction hood for an even distribution of the draw

Designing on site. I drew the dimensions and the route straight onto the wall of the venue — a 2000 + 2000 mm hood and the outlet towards the ceiling. Sketching on site is faster than paper and shows immediately what fits in the space and what doesn't.

Extraction with four connections. I connected the wall hoods to the extraction hood with four separate spigots, not one. That spreads the draw evenly along the whole length, so the extraction isn't stronger in the middle and weaker at the ends.

Fan on the roof. The motor is outside the kitchen — no noise can be heard in the venue and it's accessible for maintenance from outside. We had to put up scaffolding to lift it onto the roof.

Supply. Extraction needs air supply — without it the system would create negative pressure and not reach the output on its rating plate.

01

Saw

— What I found on site
02

Designed

— The solution, sketched on site
03

Built

— The finished job

Venue 21/burger bar

LAB. BRGR&FOOD&DRINK

Ventilation and extraction for LAB. BRGR&FOOD&DRINK. A detailed description of the project will follow.

What we did
Extraction and installation of the ventilation
03

Built

— The finished job

Catering and serving kitchens

Venue 07/catering kitchen

Bon Appetit Catering

Konská · Žilinský kraj · May 2026

This catering kitchen had a single powerful inline fan — and the draw was still very weak. Motor power isn't the same as system performance. We installed an extraction system with a kitchen fan and modified the ducts so the hood they already had could be connected. New canopies went above the combi ovens. Around the extraction zone we added a supply system with grilles so the extraction had somewhere to take air from.

What we did
Extraction system with a kitchen fan, duct modifications to connect the existing hood, new hoods above the combi ovens, supply system with grilles around the extraction zone

What I found. One inline fan, powerful on paper. In practice, a weak draw. The reason is always the same: the fan is only one part of the system. If the rest doesn't fit — the wrong type, unsuitable routing, missing air supply — the rated output means nothing.

What I did. Instead of swapping in a bigger fan, we rebuilt the whole extraction system and fitted a kitchen fan designed for greasy air. We didn't throw out the existing hood — we modified the ducts so it could be connected. Above the combi ovens, which had no extraction of their own before, we added new canopies.

Air supply. Around the extraction zone we ran a supply system with grilles. Without it, even the new system would draw a fraction of what it's designed for — the air being extracted has to get back in from somewhere.

01

Saw

— What I found on site
03

Built

— The finished job

Venue 12/canteen / serving kitchen

Care home canteen kitchen

Senica · Trnavský kraj · March 2026

The canteen kitchen of a care home. The extraction wasn't working properly. I removed everything and installed a new extraction system with a kitchen fan — with the original hoods. No new ones were bought: it was enough to swap their positions and fit them more effectively.

What we did
Removal of the faulty extraction, a new extraction system with a kitchen fan, the original hoods relocated and reconnected

What I found. Extraction that wasn't doing its job. The first question in a situation like that isn't 'how powerful a fan should we buy', but 'why doesn't it work'. Here the answer lay in the layout and the connections, not in the hoods themselves.

What I did. I removed the original hoods, swapped their positions according to where cooking actually happens in the kitchen, and connected them to a new extraction system with a kitchen fan. The motor is outside the kitchen, on the façade.

Why it was cheaper than expected. The hoods were fine — the arrangement around them was the problem. The client got working extraction without paying for new canopies. It doesn't always work out like that, but when it does, there's no point selling anything extra.

Keeping it running. A care home kitchen cooks every day and can't be shut down for long. The work was scheduled so that meals kept being served.

01

Saw

— What I found on site
03

Built

— The finished job

Venue 18/serving / catering kitchen

Serving kitchen — Ružinov

Bratislava · Bratislavský kraj · November 2025

A kitchen that prepares lunches for other restaurants in Bratislava. The chef invited me to look at the place and propose a modern replacement for the ventilation. The installation had to be done over a weekend — on weekdays the cooking goes on. A small venue that called for a non-standard anchoring solution.

What we did
Two kitchen extraction fans, a separate inline fan for the dishwasher extraction, supply system with an air heater, steel support structure for the hoods

The brief. The serving kitchen cooks lunches for other Bratislava restaurants, so it can't stop during the working week. I therefore did the whole ventilation replacement over a weekend, and the kitchen was closed for just one single day.

The ceiling problem. Both the ceiling and the walls were very fragile — nothing could be fixed or hung on them. So I had to devise and install a separate steel frame made of profiles, to which the extraction hoods were fixed independently of the ceiling.

Extraction. I installed two kitchen extraction fans — the hood needed more capacity than one fan can deliver. On top of that, a separate inline fan for the dishwasher extraction, where the steam carries no grease.

Supply. A supply system with an air heater brings fresh, tempered air into the kitchen. For the supply I cut an opening 330 mm in diameter; for the extraction I used the existing openings, so as not to interfere with the fragile walls more than necessary.

How it went. During the installation I tried not to make noise and to stick to their schedule. I did the job practically at cost, for a very low price — for a venue like this it made sense.

03

Built

— The finished job

Venue 20/religious congregation canteen

Canteen of the Premonstratensian Sisters' congregation

Vrbové · Trnavský kraj

The canteen of the Catholic congregation of the Premonstratensian Sisters. The chef asked me to replace the old ventilation system with a modern one. I designed a quality solution and carried it out — practically at cost, for a very low price. During the installation I tried not to make noise and to stick to their schedule; the kitchen was closed for only one day.

What we did
Kitchen extraction fan, a separate inline fan for the dishwasher extraction, supply system with an air heater, complete replacement of the old ventilation system

The brief. A religious community's canteen in daily use. The original ventilation was reaching the end of its life and the chef wanted a modern, reliable replacement. I designed the solution to fit the venue, not as the most expensive set-up possible.

Extraction. I installed a kitchen extraction fan plus a separate inline fan for the dishwasher extraction — the steam from the dishwasher carries no grease, so a simpler fan on its own branch is enough.

Supply. A supply system with an air heater brings fresh, tempered air into the kitchen. For the supply we cut an opening 330 mm in diameter; for the extraction we used the existing openings and didn't interfere with the walls unnecessarily.

How it went. I handled the whole replacement so the kitchen stood idle for just one single day. During the installation I made sure not to make noise or get in the way of the house's routine.

01

Saw

— What I found on site
03

Built

— The finished job

See also our services or articles on commercial kitchen ventilation.