// Air conditioning and cooling
Air conditioning for restaurants — together with ventilation
We do air conditioning in venues as a turnkey job: kitchen extraction, dining room ventilation and cooling on top. These aren't three separate jobs but one system — which is exactly why we handle them together. When one company installs the air conditioning and another the ventilation, the results usually get in each other's way.
What we do
- Supply units with a cooling section — fresh air enters the venue already cooled.
- Ceiling and cassette air conditioners for the dining room and the kitchen.
- Units chosen by the actual heat load, not by floor area in square metres.
- Routing ventilation ducts and refrigerant pipes so they don't get in each other's way.
- Installation, commissioning and handover of the whole system by one supplier.
What we don't do
We don't take on air-conditioning installation on its own without ventilation. It's not about capacity — it's about the result. Air conditioning in a venue whose ventilation isn't sorted cools air that immediately leaves through the extraction. The customer pays for the unit and the electricity, and the kitchen is still hot. We don't want to do work we know in advance will disappoint.
Why the cool air escapes outside
The extraction above the cooking line removes thousands of cubic metres of air an hour. The same volume has to get back into the venue from somewhere. If there's no controlled supply, the air is drawn from the dining room — precisely the air the air conditioning has just cooled. You're cooling the kitchen through the hood straight onto the street.
The solution isn't a stronger air conditioner, but supply air. We bring into the venue the same amount of air the extraction removes, and in summer we cool it right in the supply unit. The air conditioning in the dining room then isn't chasing a loss, it's just topping up the cooling.
Where not to put a cassette unit
A cassette air conditioner blows along the ceiling in four directions. If it's placed close to the hood, its airflow breaks up the capture zone above the cooking line — steam and smells scatter around the kitchen instead of going into the extraction. The extraction is running at full power and the owner can't understand why it doesn't draw. That's why we position the units together with the extraction route, not after it.
What else the design takes into account
- The heat load from appliances, lighting and guests — not just the room's floor area.
- Condensate drainage that can be reached during servicing.
- Noise from units in the dining room — a guest sits under them all evening.
- Access to the air-conditioner filters: in a food-service venue they clog faster than in an office.
- Winter mode: fresh supply air has to be heated, or a cold stream blows onto the guests.
We write in detail about how cooling and ventilation relate in the article air conditioning and ventilation in a restaurant. Related services: kitchen ventilation, kitchen extraction and heat recovery.
I want air conditioning and ventilation from one supplierFrequently asked questions
- Will you install just the air conditioning for us? We already have ventilation.
- If the ventilation works and has been measured, we can discuss it during the survey. But we don't install stand-alone air conditioning in a venue without controlled air supply — the cooled air would leave through the extraction and the result wouldn't match what you pay for the unit.
- Is a cassette air conditioner in the kitchen enough instead of ventilation?
- No. Air conditioning cools the air but doesn't remove steam, smells or grease — it returns the same air back into the room. Without extraction the kitchen won't be sorted.
- Why is it better to cool the air in the supply unit?
- Because you're cooling the air entering the venue, not the air already inside. In summer, hot outdoor air doesn't blow in for the dining room air conditioning to chase.
- How quickly do air-conditioner filters clog in a food-service venue?
- Faster than in an office — there's grease in the kitchen air. That's why we position the units so the filters can be reached without taking the ceiling apart.